3... INTERFACE MODULES
USING THE OMP-MODL 3-51
Digital Output Signal Connections:
To utilize an MLIM-8 channel as a Digital Output, connect the load positive
lead to an Output terminal (Chan A, B, C, D. E, F, G, or H) and the load
negative lead to one of the four Common terminals on the module terminal
strip (Figure 3... -35). Note that all of the four Common terminals are
interconnected and connect directly to the OMP-MODL circuit ground (see
Figure 3... -32). Refer to Chapter 7 for steps to generate a Terminal Strip
Wiring printout for use in making field wiring connections.
1 2 3 4 5 6 7 8 9 10 11 12
Terminal Strip
ML134
Channel A
B
Common
C
D
LOAD
LOAD
H
G
E
F
Common
Common
Common
Figure 3... -35: MLIM-8 terminal strip connections