Users Guide
®
®
Shop on line at
omega.com
For Latest Product Manuals
omegamanual.info
zSeries Wireless
Sensor System
zED, zED-P, zED-LCD,
zED-LCD-AA, zED-DC-H2,
zED-CCELL, zED-H, zCDR
zSeries
Group A
Main Menu
CHART
(5 Seconds/Div)
1 Minute
1 Minute
1 Day
1 Week
1 Month
1 Year
0
5
C/Div
50
1200
300
100%
0%
10
%/Div
90
hPa/Div
LAB 50 RH LAB 50 Pres
C hPa
Tue Jun 5 18:11:55 PDT 2009Tue Jun 5 18:05:27 PDT 2009
http://192.168.1.200
LAB 50 Temp
35 1009/25
P0 Primary
P1 LAB 50
P2 LAB 100
P3 CLN RM1
P4 CLN RM2
P5 Primary
P6 OVEN5
P7 Primary
S0 Secondary
S1 LAB 50
S2 LAB 100
S3 CLN RM1
S4 CLN RM2
S5 Secondary
S6 OVEN5
S7 Secondary
Save Current Graph
Vista de página 0
1 2 3 4 5 6 ... 91 92

Resumo do Conteúdo

Página 1 - User’s Guide

User’s Guide®®Shop on line atomega.com e-mail: [email protected] Latest Product Manualsomegamanual.infozSeries Wireless Sensor SystemzED, zED-P, zED-

Página 2

money learning a proprietary software program to log or chart the data.1.3 Description (continued)Chart scales are fully adjustable on the fly. For ex

Página 3 - TABLE OF CONTENTS

PART 2 HARDWARE2.1a Parts of the End Device (zED-P/-LCD/-AA)1 8 position DIP switch (under cover), sets the NID and DID of the End Device (see Sect

Página 4

2.1b Parts of the End Device (zED-CCELL)1 8 position DIP switch (under cover), sets the NID and DID of the End Device (see Section 2.7 for details)2

Página 5 - LIST OF FIGURES:

72.1c Parts of the End Device (zED-CCELL-H/zED-LCD-AA-H)1 8 position DIP switch (under cover), sets the NID and DID of the End Device (see Section 2.

Página 6

2.1d Parts of the End Device (zED-DC-H2)1 8 position DIP switch (under cover), sets the NID and DID of the End Device(see Section 2.6 for details)2 P

Página 7

92.1e Parts of the End Device (zED)1 8 position DIP switch (under cover), sets the NID and DID of the End Device (see Section 2.7 for details)2 Power

Página 8

102.2a Dimensions and Mounting - End Device (zED-P/-LCD/-LCD-AA/-CCELL/-H)Figure 2.2a Mounting the End Device (zED-P/-LCD/-AA/-CCELL/-H)Dimensions a

Página 9

2.2b Dimensions and Mounting - End Device (zED-DC-H2)Figure 2.2b Mounting the End Device (zED-DC-H2)11Material: PolycarbonateMakrolonProtection: NEM

Página 10

122.2c Dimensions and Mounting - End Device (zED)Position unit where required. Mark and drill holes as required, using a #6 screw.Figure 2.2c Mounti

Página 11 - ESD sensitive

132.4a Disassembly - End Device (zED-x-P/-LCD or zED-TC-P/zED-TC-LCD)You may need to open the unit for one of the following reasons:• To turn on Powe

Página 13 - SERIAL #

142.4b Disassembly - End Device (zED-x-LCD-AA or zED-TC-LCD-AA)You may need to open the unit for one of the following reasons:• To turn on Power Swit

Página 14

152.4c Disassembly - End Device (zED-x-CCELL or zED-TC-CCELL)You may need to open the unit for one of the following reasons:• To turn on Power Switch

Página 15

162.4d Disassembly - End Device (zED-DC-H2)You may need to open the unit for one of the following reasons:• To turn on Power Switch.• To access 8 Pos

Página 16

2.4e Disassembly - End Device (zED-x-LCD-AA-H or zED-x-CCELL-H)You may need to open the unit for one of the following reasons:• To turn on Power Swit

Página 17

182.4f Disassembly - End Device (zED)You may need to open the unit for one of the following reasons:• To turn on Power Switch.• To mount unit to wall

Página 18 - External

192.5 Parts of the CoordinatorFigure 2.5 Parts of the Coordinator1 Wall mounting bracket clip holes (3 places)2 Label with model and serial numbers3

Página 19 - • To turn on Power Switch

202.5 Parts of the Coordinator (continued)17 Diagnostics LED: (Yellow and Green) Diagnostics: at boot-up they light up for2 seconds, then turn off;

Página 20

212.7 DIP Switches2.7.1 DIP Switch Setup: Device ID (DID)The End Device is shipped with all DIP switches in the "OFF" position.Figure 2.7

Página 21

222.7.1 DIP Switch Setup: Device ID (DID) continuedThe End Device is shipped with all DIP switches in the "OFF" positionFigure 2.7b Devic

Página 22

232.7.2 DIP Switch Setup: Network ID (NID)Each sensor network has a unique Network ID (or NID). For the End Device (see Figure 2.7) and the Coordina

Página 23

iTABLE OF CONTENTSPart 1: Introduction1.1 Safety and EMC Considerations ...21.2 Before Y

Página 24

2.7.3 DIP Switch Setup: Ethernet - CoordinatorFigure 2.9 Ethernet - 4 Position DIP Switch Setup To set the Coordinator to factory default settings:

Página 25

252.8 Network Communication Interfaces2.8.1 10BASE-T RJ-45 PinoutThe 10BASE-T Ethernet network (RJ-45) system is used in the Coordinator for network

Página 26 - Ethernet

PART 3NETWORK CONFIGURATION3.1 Ethernet (MAC) AddressMAC (Media Access Control) address is your computer's unique hardware number.When you'

Página 27 - 2.7 DIP Switches

3.4 DNSDNS, Domain Name System enables computers and devices to be recognized over anetwork based on a specific name instead of IP addresses. For exam

Página 28

283.5.2 Changing TCP/IP Properties on Your ComputerGo to your computer’s Control Panel then Network Connections. Pick the network with the proper Et

Página 29 - OFF ON

29PART 4OPERATIONSThis Coordinator can be used and configured in several ways, depending on user’spreference and network setup. It can be configured u

Página 30 - "OFF" Position)

304.1 iConnect SoftwareThe Coordinator may also be assigned an IP Address by using the iConnect software.a) Download the iConnect software from the w

Página 31

314.1 iConnect Software (continued)d) To access the zSeries system for Configuration:Click on the "View Webpage" button, you will access th

Página 32

324.2 Setting a New IP Address over the NetworkBesides using the iConnect software, you may use the Coordinator’s default IP address toaccess it and a

Página 33

33334.3 Coordinator’s Configurations and OperationsThe Blue LED should blink for about 8 seconds and then stay on. It indicates that theCoordinator i

Página 34

iiTABLE OF CONTENTS(continued)4.3.4 Chart ...394.3.5 Diagno

Página 35

4.3.1 Power Up DeviceTo verify that an End Device is working before deploying remotely, install batteries andpower it on right next to the Coordinato

Página 36

354.3.2 Get Readings from the End DeviceOnce you see the End Device’s LED blinking periodically, it means it is sending datawhich will appear on the

Página 37 - Section 4.3 for details

364.3.2 Get Readings from the End Device (continued)The "Readings" fields are defined as follows: Title: Coordinator’s name, assigned in &q

Página 38 - ACCESS CONTROL

374.3.3 Java Runtime Environment SetupIf your computer does not have Java installed, please download from java.sun.com. Youcan change the Java settin

Página 39 - ADMINISTRATOR

4.3.3.2 Browser Proxy SelectionAccessing Coordinators within your internal network• Usually when the computer and Coordinators are on an internal net

Página 40

4.3.4 ChartClick on , from the Home Page,the following page will appear. Selectthe proper Group to view the Chart. In a few seconds the following pag

Página 41 - READINGS: BY GROUPS

4.3.4 Chart (continued)Title: Coordinator’s name, assigned in "Configuration" page.Save Current Graph: Save the current graph in PNG (Portab

Página 42

4.3.5 DiagnosticClick on , the following page will appear.Figure 4.13 DiagnosticDate and Time: Most recent time when data is received.Save Current

Página 43

4.3.6 ConfigurationClick on from the Home Page, the following page will appear. Figure 4.14 Configuration Name: Coordinator name [maximum of 16 alp

Página 44

4.3.6 Configuration (continued)PID: The Personal Network ID is automatically detected and displayed.Channel: Choose the operation channel defined in I

Página 45 - CHART: BY GROUPS

iiiLIST OF FIGURES:Figure 1.1 zSeries Wireless System on the Ethernet Network...4Figure 2.1a Parts of the End Device -

Página 46

4.3.7 Sensor Setup (continued)Figure 4.16 Sensor Setup #: Sensor ID configured by dip switches on the End Device. Click on the number to viewand mod

Página 47 - Diagnostic

4.3.7 Sensor Setup (continued)Figure 4.17a Sensor ParametersSensor Name: Name of this End Device.Update (seconds): How often this sensor is sendin

Página 48 - CONFIGURATION

4.3.7 Sensor Setup (continued)Offset: If it is determined that the readings are slightly off, the user can manually assignnumerical values to adjust

Página 49 - SENSOR SETUP: BY GROUPS

4.3.8 Access ControlThis section describes the "Access Control" page of the Web interface. This page allowsthe users to set up the network

Página 50 - SENSOR SETUP

4.3.8 Access Control (continued)IP Address: The IP (Internet Protocol) address is a 32-bit number that identifies eachsender or receiver of informati

Página 51 - SENSOR PARAMETERS

494.5 HTTPget Program (continued) Whenever Terminal Server service (using Port 2000 by default) is required, the # ofconnections must be set to a val

Página 52

4.5.2 HTTPget and ARP to Setup Device IP Address Use the iConnect software, which may be downloaded from our website, to dothese IP changes whenever

Página 53

4.6 ARP Protocol (continued)The following window shows examples of arp commands and responses.• Your computer has an IP address of 192.168.1.118• The

Página 54

4.7 iLog SoftwareThis is an Excel application software that can log temperature, humidity and barometricpressure from the Coordinator over the local

Página 55 - Sensor Value & Unit

4.7 iLog Software (continued)Table 4.1 iLog Excel ApplicationsThe iLog application actually consists of several Excel files, though most supportedde

Página 56

ivLIST OF FIGURES:(continued)Figure 4.21 iLog Software Logging Data for End Device #1, 3, 4 ...52Figure 4.22 Mail Notifier

Página 57 - 4.6 ARP Protocol (continued)

4.8 Mail Notifier SoftwareFor complete information of how to use the Mail Notifier software, click on the Help menuof the main window.The Mail Notifi

Página 58

4.8.2 Program Options Setup and ConfigurationComplete program setup requires: • Entering a recipient for the email• Specifying connection details to

Página 59

564.8.3 Device Setting and ConfigurationMake sure that the Coordinator is configured (using web access, see Figure 4.17) to thesettings below. TCP Co

Página 60 - Alerts List

4.8.3 Device Setting and Configuration (continued)Figure 4.24 Mail Notifier Device Setting 4.8.4 Sending Text Messages to a Cell PhoneOnce you inst

Página 61 - Mail Server

PART 5ENVIRONMENT / OPERATING CONDITIONSEnd Device/Coordinator are designed to be fixed mounted and operated in a clean anddry environment. Care shoul

Página 62

5.1 General Deployment Guidelines (continued)7. Where possible, try to ensure an uninterrupted line-of-sight between nodes.Avoid obscuring objects (

Página 63 - Only Monitor Access

5.2 With Line-of-SightWhen installing your Coordinator it is important to position your device in such a way tooptimize the antenna location within w

Página 64

5.3 Without Line-of-SightWhen line-of-sight is not possible, signal penetrates and is reflected by different objectsto reach the destination. Therefo

Página 65

5.5 Fine Adjustment in Performance1. To avoid interference from WiFi / IEEE 802.11, one could consult the figure below tochoose the best channel thro

Página 66

PART 6 SPECIFICATIONSSENSOR SPECS (zED, zED-P, zED-LCD, zED-LCD-AA, zED-CCELL, zED-DC-H2, zED-H)RELATIVE HUMIDITYAccuracy/Range: ±2% for 10 to 90%;

Página 67

NOTES, WARNINGS and CAUTIONSInformation that is especially important to note is identified by the following labels:• NOTE • WARNING or CAUTION• IMPORT

Página 68 - 2120191817161514131211

64EXTERNAL PROBE SPECIFICATIONS (zED, zED-P, zED-LCD, zED-LCD-AA, zED-CCELL, zED-DC-H2, zED-THP2-x-H)Industrial Probe: SS 316 housing, 137 mm x Ø16 mm

Página 69 - PART 6 SPECIFICATIONS

INTERFACE SPECIFICATIONS (zCDR)Ethernet: Standards Compliance IEEE 802.3 10Base-T (RJ45)Supported Protocols: TCP/IP, ARP, ICMP, DHCP, DNS, HTTP, and T

Página 70

POWER (zED)Alkaline Battery: Two AA 1.5 Vdc, suppliedLifetime: Estimated 2 years with frequency of 1 reading per 2 minutesPOWER (zED-P, zED-LCD)Power

Página 71

ENVIRONMENTOperating Temperatures:zED, zED-CCELL, -CCELL-H, -DC-H2: -18º to 55ºC (-0.4º to 131ºF) 90% RH, non-condensingzED-P: -20º to 70ºC (-4º to 15

Página 72 - Consumption: 1.1 W

PART 7FACTORY PRESET VALUESPRESET PARAMETERS FACTORY DEFAULTSIP Address 192.168.1.200Gateway Address 0.0.0.0Subnet Mask 255.255.255.0Device Host Name

Página 73

APPENDIX A GLOSSARYUser of this manual should be familiar with following definitions:ARP (Address Resolution Protocol) is a protocol for mapping an In

Página 74

Appendix B IP AddressAn IP address is a unique 32-bit address assigned to a computer and includes:• A network ID number identifying a network.• A host

Página 75

Appendix C IP NetmaskIP Netmask or Subnet Mask is a 32-bit pattern of ones and zeros used to determinenetwork portion of an IP address from the host p

Página 76

Appendix D ASCII ChartASCII Dec Hex Binary ASCII Dec Hex BinaryChar No Parity Char No parityNUL 00 00 00000000 @ 64 40 01000000SOH 01 01 00000001 A 65

Página 77

Appendix D ASCII Chart Continuation/ 47 2F 00101111 o 111 6F 011011110 48 30 00110000p112 70 011100001 49 31 00110001q113 71 011100012 50 32 00110010

Página 78

2PART 1 INTRODUCTION1.1 Safety and EMC ConsiderationsRefer to the Environment/Operating Conditions Section.Warning: the following parts of the unit

Página 79

Appendix E iLog Error MessagesError # Description Note-8003 User stopped logging readings.-10005 Failed to find the Coordinator. Ethernet cable is di

Página 80

Appendix F ASCII / TELNET COMMANDS TABLECommand Device / Group ID Description (see notes below if *) ExampleERCR Device ID: 000 – 031 Get continuous

Página 81

76Appendix F ASCII /TELNET COMMANDS TABLE (continued)* An example of the status of an End Device Command: EQNG00AResponse: 7 EngrLAB 01000010 2.07 is

Página 82

Appendix G Frequently Asked Questions (FAQ)Q: Java applet is not loaded?A: Check Java Setting (icon in Control Panel). Make sure cache is disabled

Página 83

Appendix G Frequently Asked Questions (FAQ) (continued)Q: The Chart trend line for all the variables are broken, what could be wrong?A: It indicat

Página 84

Appendix H Warnings and Regulatory InformationIn order to comply with FCC radio frequencies (RF) exposure limits, dipole antennasshould be located at

Página 85

Appendix H Warnings and Regulatory Information (continued)UNIT’S MAXIMUM POWER LEVELS AND ANTENNA GAINSAntenna Gain SMA Connector Maximum Radiate

Página 86 - Figure I.1 Figure I.2

Appendix I Sensor Information (continued)I.3 Storage Conditions and Handling InstructionsIt is of great importance to understand that a humidity s

Página 87

NOTES_________________________________________________________________________________________________________________________________________________

Página 88

NOTES_________________________________________________________________________________________________________________________________________________

Página 89

31.3 Description (continued)The End Devices transmit up to 300 feet/91m (zED) or 3280 feet/1000m (zED-P/-LCD/-AA/-CCELL/-DC-H2), without obstructions

Página 90

NOTES_________________________________________________________________________________________________________________________________________________

Página 91 - RETURN REQUESTS/INQUIRIES

WARRANTY/DISCLAIMEROMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of one (1) yearfrom the

Página 92 - Shop on line at omega.com

M4585/1112Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course!Shop on line at omega.comTEMPERATURER Thermocouple, R