Página 1 - User’s Guide

omega.com e-mail: [email protected] latest product manuals:omegamanual.infoUser’s GuideUSB-47618 Channel Relay/Isolated DIUSB Data Acquisition Module

Página 2

Figure 1.1: Installation Flow Chart 5 Chapter 1

Página 3 - USB Data Acquisition Module

1.4 Software Overview OMEGA offers a rich set of DLL drivers, third-party driver support and application software to help fully exploit the function

Página 4 - Contents

1.5 Device Driver Programming This section will provide a roadmap to demonstrate how to build an appli- cation from scratch using the Device Drivers

Página 5

1.5.2 Programming with Device Drivers Function Library The Device Drivers offer a rich function library that can be utilized in various application pr

Página 6 - Introduction

2 2 Installation This chapter has a package item check- list, proper instructions about unpack- ing and step-by-step procedures f

Página 7 - Chapter 1 Introduction

Chapter 2 Installation 2.1 Unpacking After receiving your USB-4761 package, please inspect its contents first. The package should contain the fo

Página 8 - 3 Chapter 1

2.2 Driver Installation We recommend you install the software driver before you install the USB-4761 module into your system, since this will guaran

Página 9 - 1.3 Installation Guide

Step3: Click Continue, and select the Installation option Step4: Select the specific device and then just follow the installation instructions step by

Página 10 - 5 Chapter 1

Figure 2.2: Device Name on the Device Manager Note: If your module is properly installed, you should see the device name of your module listed o

Página 11 - 1.4 Software Overview

After your module is properly installed with your system, you can now configure your device using the Device Manager that has itself already been in

Página 12 - 1.5.1 Programming Tools

Servicing North America:U.S.A.: One Omega Drive, Box 4047ISO 9001 Certified Stamford, CT 06907-0047Tel: (203) 359-1660FAX: (203) 359-7700e-mail: info@

Página 13 - USB-4761 User Manual 8

Step2: You can view the device(s) already installed on your system (if any) in the Installed Devices list box. If you haven’t installed any devices, y

Página 14 - Installation

Figure 2.5: The Device Setting Dialog Box Note: Please refer to the software manual Start/Programs/Omega USB-4700 series/Device Driver’s Manual f

Página 15 - Chapter 2 Installation

2.5.1 Testing Digital Input Function Click the Digital Input tab to show the Digital Input test panel as seen below. By the color of the LEDs, you can

Página 16 - 2.2 Driver Installation

. Figure 2.7: Digital Output Tab in Device Test Dialog Only after your module device is properly set up, configured and tested, can the device ins

Página 17 - 2.3 Hardware Installation

Step2: Right click the “Unplug or Eject Hardware” icon on your task bar. Figure 2.8: Unplug or Eject Hardware Dialog Step3: Select “USB4711 Device

Página 18 - 13 Chapter 2

Step4: Unplug your USB device from the USB port. Note: Please make sure that you have closed the application programs before unplugging the USB dev

Página 19 - 2.4.1 Setting Up the Device

3 2 Signal Connections This chapter provides useful informa- tion on how to connect input and output signals to the USB-4761 via the I/

Página 20 - 2.4.2 Configuring the Device

Chapter 3 Signal Connections 3.1 Overview Maintaining good signal connections is one of the most important factors in ensuring that your applica

Página 21 - 2.5 Device Testing

Figure 3.1: I/O Connector Pin Assignment 23 Chapter 3

Página 22 - 17 Chapter 2

3.2.2 I/O Connector Signal Description Table 3.1: I/O Connector Signal Description Signal Name Description NO<0~7> Normally Open pin of rel

Página 23 - 2.6 Hardware Uninstallation

USB-4761 8-channel Relay / Isolated DI USB Data Acquisition Module User Manual

Página 24 - 19 Chapter 2

3.3 Isolated Digital Input Connections 3.3.1 Single-ended Channel Connections USB-4761 has 8 isolated digital input channels. Each of isolated digi

Página 25 - USB-4761 User Manual 20

3.5 Field Wiring Considerations • When you use USB-4761 to acquire data from outside, noises in the environment might significantly affect the accu

Página 27 - 3.2 I/O Connectors

Appendix A Specifications A.1 Isolated Digital Input Channels 8 Optical Isolation 2,500 VDC Opto-isolator response time 25us Input Voltage VIH

Página 28 - 23 Chapter 3

A.3 General I/O Connector Type Removable 10-pin screw terminal x 5 Dimensions 132 X 80 X 32 mm (5.2” X 3.2” X 1.3”) Power Consumption 60mA@+5V t

Página 29

USB-4761 User Manual 30

Página 31 - USB-4761 User Manual 26

Appendix B Function Block USB-4761 User Manual 32

Página 32 - Specifications

WARRANTY/DISCLAIMEROMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials andworkmanship for a period of 13 months from date of

Página 33 - Appendix A Specifications

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course!Shop online at omega.comTEMPERATURE䡺⻬Thermocouple, RTD & Th

Página 34 - 29 Appendix A

Contents Chapter 1 Introduction ... 2 1.1 Features ...

Página 35 - USB-4761 User Manual 30

Table 3.1:I/O Connector Signal Description ... 24 3.2.3 LED Indicator Status Description ... 24 Table 3.2:L

Página 36 - Function Block

1 2 Introduction This chapter will provide information on the features of the DAS module, a quick start guide for installation, a

Página 37 - USB-4761 User Manual 32

Chapter 1 Introduction Thank you for buying the USB-4761 data acquisition module. The USB-4761 is a powerful data acquisition (DAS) module for the

Página 38 - RETURN REQUESTS/INQUIRIES

1.1.1 Robust Protection The USB-4761 digital input channels feature a robust isolation protection for industrial, lab and machinery automation applica

Página 39 - M4572/0907

1.2 Applications • Industrial On/Off control • Switch status sensing • Digital I/O control • Industrial and lab automation • SMT/PCB machi